TOCII CA72TOC

High-temperature TOC analyzer

CA72TOC

  • Industrial applications with varying pH values and high salt loads

  • High accuracy, low maintenance

  • Measuring time only 7 minutes
  • Measuring range:
    0.25 - 12,000 mg/l,
    can be extended optionally

Více informací o CA72TOC

EZ-TOC II CA52TOC

Continuous real-time wet-chemical TOC analyzer

CA52TOC

  • Monitoring of organic carbon in water/wastewater, industrial processes, methanol dosage

  • UV-supported chemical low temperature oxidation
  • Various measuring ranges:
    0 - 10,000 mg/l TOC, measurements down to 15 ppb
  • Effective self monitoring - follows ISO and EPA approved methods

Více informací o CA52TOC

STIP-scan CAS74

In-situ analyzer for 9 parameters

CAS74

  • UV/VIS spectroscopic system for nitrate, COD, BOD, TOC, SAC, SS, SV, SI and turbidity

  • Various measuring ranges depending on parameter

  • No chemicals or reagents required

  • Self-cleaning and low maintenance


Více informací o CAS74

STIP-scan CAM74

Transmitter for measuring of 9 parameters

CAM74

  • UV/VIS spectroscopic system for nitrate, COD, BOD, TOC, SAC, SS, SV, SI and turbidity

  • Various measuring ranges depending on parameter

  • No chemicals or reagents required

  • Self-cleaning and low maintenance


Více informací o CAM74

Stamosens CSS70 / CSM750

In-situ analysis system for SAC

CSM750

  • Wastewater
  • Sensor and transmitter for dissolved organic substances
  • Various measuring ranges:
    0.3 … 50 1/m up to 15 … 700 1/m
  • Economy-priced and ecological measuring process: no chemicals required

Více informací o CSM750

BIOX-1010

Continuous short-time BOD analyzer

  • Load control, monitoring of limit value, discharge or production loss, airport wastewater
  • Various measuring ranges:
    5 … 1,200 mg/l BOD up to
    20 …100,000 mg/l BOD
  • Response time 3 minutes, reagent-free measurement

More information about BIOX-1010

PHOENIX-1010

Continuous short-time COD analyzer

  • Control of inlet, outlet, industrial discharge, raw wastewater
  • Uses ozone for oxidation
  • Various measuring ranges:
    10 - 100,000 mg/l COD
  • Response time 3 to 15 minutes

More information about PHOENIX-1010

PHOENIX-thermcat

High-temperature COD analyzer

  • Raw wastewater, inlet, outlet, cooling water, industrial discharge
  • High temperature catalytic oxidation
  • Various measuring ranges:
    4 - 10,000 mg/l COD
  • Automatic self-calibration and self-control

More information about PHOENIX-thermcat