Proline Prosonic Flow
B 200 Ultrasonic flowmeter

Picture of Ultrasonic flowmeter Proline Prosonic Flow B 200 / 9B2B ©Endress+Hauser

Proline Prosonic Flow B 200

The Ultrasonic Flow Measuring Principle

Endress+Hauser solution for simultaneous measurement of flow and methane content in Wastewater treatment plants (3'05")

Endress+Hauser solution for simultaneous measurement of flow and methane content in Biogas plants (3'05")

Endress+Hauser solution for simultaneous measurement of flow and methane content in Landfill gas plants (3'18")

HistoROM data storage concept

The device for accurate, reliable biogas measurement with loop-powered technology

Prosonic Flow B 200 is the specialist for accurate and reliable measurement of wet biogas and digester gas,even under fluctuating process conditions. With its unique integrated real-time methane fraction analysis, Prosonic Flow B 200 enables continuous measurement and monitoring of gas flow as well as gas quality. In addition to efficient process control and energy balancing, Heartbeat Technology ensures compliance and process safety at all times.

Rychlý výběr

Vyberte si z námi navrhovaných možností
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

nebo

Individuální konfigurace

Pokračujte ve svém výběru ze všech možných volitelných možností
  • Výhody

    • Integrated real-time methane fraction measurement

    • Optimized for low pressure gas – specialized sensor design

    • No additional pressure loss – full bore design

    • Process transparency – diagnostic capability

    • Convenient device wiring – separate connection compartment

    • Safe operation – no need to open the device due to...

  • Oblast použití

    • The measuring principle is unaffected by gas composition

    • Inline flowmeter designed for wet biogas and digester gas under fluctuating process conditions.

    Device properties:

    • Multivariable device: flow, temperature and methane

    • Medium temperature: 0 to 80...

Technické informace

Zpět

Details

  • Měřicí princip

    Ultrasonic flow

  • Product headline

    Přístroj pro přesné a spolehlivé měření bioplynu s dvouvodičovým připojením.
    Možnost měření podílu metanu v reálném čase. Průtokoměr určený pro inline měření bioplynu a plynu z vyhnívací nádrže při měnících se procesních podmínkách.

  • Sensor features

    Vhodné pro nízké tlaky plynu – speciální konstrukce senzoru. Zařízení nezpůsobuje tlakovou ztrátu – provedení „plného otvoru". Transparentnost procesu – možnost diagnostiky. Zařízení na měření více veličin: průtok, teplota a metan. Teplota média: 0 až 80 °C.

  • Transmitter features

    Snadné elektrické připojení – oddělená svorkovnice. Bezpečný provoz – pro odečítání hodnot slouží dotykové ovládání a prosvícený displej – není potřeba zařízení otvírat. Integrovaná funkce ověření – technologie Heartbeat. Technologie napájení po smyčce. Robustní dvoukomorový kryt.

  • Nominal diameter range

    Verze s jednou dráhou měření: DN 50 (2"), DN 80 (3")
    Verze se dvěma dráhami měření: DN 100 až 200 (4" až 8")

  • Wetted materials

    Senzor: 1.4404/1.4435 (316L)
    Převodník: HNBR
    Teplotní senzor (volitelná možnost): AFM 34

  • Measured variables

    Objemový průtok, normovaný objemový průtok, normovaný objemový průtok metanu, průtok energie, metanová frakce, kalorifická hodnota, teplota

  • Max. measurement error

    Objemový průtok (standard):
    ‐ ±1,5 % o. h. pro 3 až 30 m/s
    ‐ ±3 % o. h. pro 1 až 3 m/s
    Objemový průtok (volitelná možnost):
    ‐ ±0,1 % h. c. s. pro 0,3 až 1 m/s
    ‐ ±1,5 % o. h. pro 1 až 30 m/s

  • Měřicí rozsah

    Standard: 1 až 30 m/s
    Volitelná možnost: 0,3 až 30 m/s

  • Max. process pressure

    11 bar a (159 psi a)

  • Medium temperature range

    0 až +80 °C

  • Ambient temperature range

    Materiál příruby – uhlíková ocel: −10 až +60 °C
    Materiál příruby – nerezová ocel: −40 až +60 °C

  • Transmitter housing material

    AlSi10Mg, lakovaný; 1.4404 (316L)

  • Degree of protection

    IP 66/67, kryt typu 4X

  • Display/Operation

    Čtyřřádkový podsvícený displej s dotykovým ovládáním

    (ovládání z vnějšku)

    Nastavení možné prostřednictvím místního displeje a ovládacích nástrojů

  • Outputs

    4–20 mA HART (pasivní)

    4–20 mA (pasivní)

    Pulzní/frekvenční/spínaný výstup (pasivní)

  • Inputs

    Proudový vstup 4–20 mA (pasivní)

  • Digital communication

    HART

  • Power supply

    12 až 35 V DC (4–20 mA HART s pulzním/frekvenčním/spínaným výstupem nebo bez něj)
    12 až 30 V DC (4–20 mA HART, 4–20 mA)
    12 až 35 V DC (4–20 mA HART, pulzní/frekvenční/spínaný výstup, vstup 4–20 mA)
    9 až 32 V DC (PROFIBUS PA, pulzní/frekvenční/spínaný výstup)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, JPN

  • Metrological approvals and certificates

    Kalibrace provedená na akreditovaných kalibračních zařízeních (podle ISO/IEC 17025)

  • Pressure approvals and certificates

    PED

  • Material certificates

    3.1 materiálový certifikát (smáčené díly)

Dokumenty / software

Příslušenství / náhradní díly

Nr
Order code
Specification
  • 34
    • Nr 34 Order code 71108602

      I/O module Flow, 2-wr. 2x4-20mA,HART, Ex

      Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: FTM50/FTM51/FTM52. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Order code 71128617

      Overvoltage protection (OVP10),1-Channel

      4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71128619

      Overvoltage protection (OVP20),2-Channel

      4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71197334

      Transmitter electronics FHX50

      Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.

    • Order code

      Remote display FHX50 please order with separate order structure.

    • Order code 71296840

      Plug M12, VA

      To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.

  • 30
  • 34
  • 37
    • Nr 37 Order code 71110280

      Terminal set 2-wire, I/O module

      Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 34
    • Nr 34 Order code XPD0016-

      I/O module, 2-wire, 4-20mA,HART, PFS, Ex

      Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.

    • Nr 34 Order code XPD0018-

      I/O,2-wire,4-20mA,HART,PFS,4-20mA input

      Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. 1x current input.

  • 40
    • Nr 40 Order code XPD0024-

      Display module, SD02, push buttons

      For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.

    • Nr 40 Order code XPD0025-

      Display module, SD03, Touch Control

      For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.

  • 20
    • Nr 20 Order code 71110281

      Cover GT18 316L, HNBR

      Material: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 20 Order code 71110282

      Cover GT18 316L, sight glass, HNBR

      Material: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110291

      Cover GT18 316L, terminal Ex, HNBR

      Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 25 Order code 71110284

      Cover GT18 316L, terminal Ex d, HNBR

      Material: 316L. O-ring EPDM /PTFE coated. Usage: terminal compartment Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 25 Order code 71185516

      Cover GT18 316L, Terminal, OVP, HNBR

      Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57, FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Prowirl 200.

  • 20
    • Nr 20 Order code 71110299

      Cover GT20 Alu, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 20 Order code 71110297

      Cover GT20 Alu, sight glass, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110301

      Cover GT20 Alu, Terminal Ex, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71110302

      Cover GT20 Alu, Terminal Ex d, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71185517

      Cover GT20 Alu, Terminal, OVP, HNBR

      Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 15
  • 65
    • Nr 65 Order code 71110303

      Sealing set GT18/GT19/GT20, EPDM, HNBR

      Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 19
    • Nr 19 Order code 71115174

      Housing filter 316L, GT18, 1 set

      Consists of: 2x filter plug metall 316L. 1x pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 19 Order code 71115175

      Housing filter Brass/Ni GT19/20, 1 set

      Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 17
    • Nr 17 Order code 71115176

      Set housing securing clamps

      Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71162242

      Weather prot. cover GT18/GT19/GT20, 316L

      Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/ FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 9B2BXX-

      Transmitter Prosonic Flow B 200, 9B2BXX

  • 53
  • 51

Stahování