Proline Prosonic Flow 92F
Ultrasonic flowmeter
Highly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs
Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow (standard):
- ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s) -
Measuring range
0.5 to 10 m/s (1.6 to 33 ft/s)
-
Medium temperature range
-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional -
Max. process pressure
PN 40 / ASME Cl. 300 / JIS 20K
-
Wetted materials
Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432
-
Quick selection
Individual configuration
-
Benefits
Safe design for process industries – international hazardous area approvals
No additional pressure loss – full-bore design
Process transparency – diagnostic capability
Easy installation and reduced installation costs – loop-powered transmitter
Fully...
-
Field of application
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry
Device properties:
Full compliance...
Documents / Manuals / Software
-
Proline Prosonic Flow 92F
Technical Information (SI units)
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
Technical Information (TI) -
Proline Prosonic Flow 92F
FOUNDATION Fieldbus
Operating Instructions
Ultrasonic Flow Measuring System
Operating Instruction (BA) -
Proline Prosonic Flow 92F
Operating Instructions
Ultrasonic Flow Measuring System
Operating Instruction (BA) -
Prosonic Flow 92F PROFIBUS PA
Operating Instructions
Ultrasonic Flow Measuring System, 2-Wire loop powered inline
flowmeterOperating Instruction (BA) -
Prosonic Flow 92
Operating Instructions
Temporary volume flow measurement of liquids with
Operating Instruction (BA) -
Proline Prosonic Flow 92F
Brief Operating Instructions
Ultrasonic flow measuring system
Two-wire inline flowmeterShort Instruction (KA)09/09English -
Replacing transmitter parts
Prowirl 72, 73, Prosonic Flow 92
Installation Instructions (EA) -
Installing sensor parts
Installation Instructions
Prosonic Flow 92F, Prowirl 72, 73, Prowirl 200
Installation Instructions (EA) -
Prowirl 72, 73, Prosonic Flow 92 F
Installation Instruction
Installing sensor parts
Installation Instructions (EA) -
Bus plug FF
Installation Instructions
Promag 53, 55, Promag 200, Promass 83, Promass 200, Prowirl 72, 73,
Prowirl 200, Prosonic Flow 92, 93Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Repair kit cover remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65Installation Instructions (EA) -
Replacing the cable for the Sensor
Installation Instructions
Prosonic Flow 92F
Installation Instructions (EA) -
Replacing cover and O-ring
Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73Installation Instructions (EA) -
Prosonic Flow 92F
ATEX II3G
Ex-Dokumentation/Ex documentation/Documentation Ex
Safety instructions for electrical apparatus for explosion-hazardous
areas according to Directive 94/9/EC (ATEX)Ex Safety Instructions (XA) -
Proline Prosonic Flow 92F
NEPSI Zone 1
Safety Instructions
Ex d version
Ex Safety Instructions (XA) -
Proline Prosonic Flow 92F
NEPSI Zone 1
Safety Instructions
Ex i version
Ex Safety Instructions (XA) -
Prosonic Flow 92F
Division 1 IS (Ex-i Intrinsically safe version)
Ex-Dokumentation/Ex documentation/Documentation Ex
Safety instructions for electrical apparatus for explosion-hazardous
areas according to FACTORY MUTUAL standards and CANADIAN
STANDARDS ASSOCIATIONEx Safety Instructions (XA) -
Prosonic Flow 92F
Division 1 (Ex-d version)
Ex-Dokumentation/Ex documentation/Documentation Ex
Safety instructions for electrical apparatus for explosion-hazardous
areas according to FACTORY MUTUAL standards and CANADIAN
STANDARDS ASSOCIATIONEx Safety Instructions (XA) -
Prosonic Flow 92F
ATEX II2G & II1/2G; IECEx Zone 1 & Zone 0/1
Ex-d version (XP)
Ex-Dokumentation / Ex documentation / Documentation Ex
Safety instructions for electrical apparatus for explosion-hazardous
areas according to Directive 94/9/EC (ATEX) and IEC 60079-0Ex Safety Instructions (XA) -
Prosonic Flow 92F
ATEX II2G & II1/2G; IECEx Zone 1 & Zone 0/1
Ex-i version (IS)
Ex-Dokumentation / Ex documentation / Documentation Ex
Safety instructions for electrical apparatus for explosion-hazardous
areas according to Directive 94/9/EC (ATEX) and IEC 60079-0Ex Safety Instructions (XA) -
Proline Prosonic Flow 92F
JPN:Zone 1(Ex-d バージョン)
安全上の注意事項
危険場所における電気機器の安全上の注意事項
Ex Safety Instructions (XA) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Prosonic Flow 92F/93, t-mass 65, Promag 53/55, Promass 83,
Prowirl 72/73
Special Documentation
Supplementary information to following modifications: Bus plug wiring
configuration for FOUNDATION Fieldbus devicesSpecial Documentation (SD) -
Information
NEMA 6P
Special Documentation
Proline Promag W, P
Special Documentation (SD) -
Proline Prosonic 92F
Information on rupture disk order option
Special Documentation
Sensor housings with integrated rupture disks are optionally available.
Special Documentation (SD) -
Proline Prosonic Flow 92F
PED / DGRL
Special Documentation
The information relates to devices which have been examined in
accordance with the guidelines of the Pressure Equipment Directive
97/23/EC. (PED)
Die Angaben beziehen sich auf Geräte, welche nach Vorschriften der
Druckgeräterichtlinie 97/23/EG geprüft worden sind. (DGRL)Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 PROFIBUS PA: 1.00.02Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 HART: 1.01.01Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 PROFIBUS PA: 1.01.04Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 FOUNDATION Fieldbus:
1.01.03Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 HART: 1.00.03Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 HART: 1.01.03Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 PROFIBUS PA: 1.01.02Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 FOUNDATION Fieldbus:
1.01.04Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 PROFIBUS PA: 1.01.01Manufacturer Information (MI) -
Proline Prosonic Flow 92
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 92 FOUNDATION Fieldbus:
1.01.01Manufacturer Information (MI) -
Kosztowne pomiary przeplywu
Pomiar przepływu bez strat ciśnienia
Publications (PU)12/13Polish -
Kosztowne pomiary przepływu- NiS_01_2012
Sieci wodociągowe, układy zasilania kotłów parowych w wodę,
rurociągi paliwowe – to przykładowe instalacje, w których do pomiaru
przepływu chętnie używa się tradycyjnych metod, bazujących na
różnicy ciśnień. Dzięki nowszym metodom pomiaru przepływu cieczy
koszty te można w łatwy sposób wyeliminować.Publications (PU)04/12Polish -
Pomiary przepływu apa_05_2011
Zastosowanie w procesach przemysłowych nowoczesnej
i nieinwazyjnej ultradźwiękowej technologii pomiaru przepływu, która
oparta jest na pomiarach czasu przejścia fali ultradźwiękowej.Publications (PU)03/12Polish -
Zasilanie przepływomierzy- art CE 11_2011
Dwuprzewodowe zasilanie urządzeń obiektowych oznacza, że
dostarczenie energii zasilającej oraz transmisja sygnału pomiarowego
są realizowane tymi samymi, dwoma przewodami.
Popularna infrastruktura kablowa dla większości urządzeń
pomiarowych, jak przetworniki ciśnienia, temperatury czy poziomu.Publications (PU)03/12Polish -
Prosonic Flow 92F apa_02_2011
Prosonic Flow 92F– przepływomierz ultradźwiękowy
do skomplikowanych warunków instalacyjnych. Jest
przepływomierzem
ultradźwiękowym, który łączy bardzo dokładny czujnik przepływowy
z
ekonomicznym zasilaniem z linii sygnałowej.Publications (PU)03/12Polish -
Prosonic Flow 92F- NiS_10_2011
Prosonic Flow 92F– przepływomierz ultradźwiękowy
do skomplikowanych warunków instalacyjnych. Jest przepływomierzem
ultradźwiękowym, który łączy bardzo dokładny czujnik przepływowy z
ekonomicznym zasilaniem z linii sygnałowej.Publications (PU)03/12Polish -
Rewolucja w przepływomierzach Coriolisa CE 02_2011
Promass E 200 - pierwszy dwuprzewodowy
przepływomierz Coriolisa, zasilany bezpośrednio z pętli prądowej
4...20mA i nie wymagającydodatkowych konwerterów.Publications (PU)03/12Polish -
Flow measurement in utilities - for the US Market
Energy management in your hands - customized solutions for
compressed air, gas, steam and waterCompetence Brochure (CP)12/10English -
Flyer : Prosonic Flow 92F
&
12503;&
12525;&
12521;&
12452;&
12531;
&
12503;&
12525;&
12477;&
12491;&
12483;
&
12463;&
12501;&
12525;&
12540; 92F
&
19990;&
30028;&
21021;&
65281;2&
32218;
&
24335;&
12452;&
12531;&
12521;&
12452;&
12531;&
36229;&
38899;&
27874;
&
27969;&
37327;&
35336;Innovations (IN)12/09Japanese -
Proline Prosonic Flow 92F
Ультразвуковой расходомер для химической и нефтехимической отраслей
промышленностиInnovations (IN)10/10Russian -
GSD Single, GSD_EH_PA_FL_Prosonic_Flow_0x154C_V01_00_00_PALIB, 22.04.2014
(Flow, Prosonic Flow, 0x1
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_ProsonicFlow92_0x154C_0x02_0x01, 14.02.2018 (Flow, Prosonic Flow, 0x154C)
PROFIBUS PA,
PDM Version: 6.0 SP5, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_FL_ProsonicFlow_92_0x1061_0x01_0x01, 07.04.2014 (Flow, Prosonic Flow, 0x1061)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow92_0x0061_0x01_0x01, 14.11.2018 (Flow, Prosonic Flow, 0x0061)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_ProsonicFlow92_0x154C_0x01_0x01, 25.01.2019 (Flow, Prosonic Flow, 0x154C)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow92_0x0061_0x02_0x01, 14.11.2018 (Flow, Prosonic Flow, 0x0061)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ProsonicFlow_92_V1_00_xx_DevRev1, 22.10.2020 (Flow, Prosonic Flow, 0x1061)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, ProsonicFlow_92_PA_FW1_01_zz_Dev_Rev_2, 21.10.2020 (Flow, Prosonic Flow, 0x154C)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, ProsonicFlow_92_PA_V1_00_xx, 21.10.2020 (Flow, Prosonic Flow, 0x154C)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, ProsonicFlow_92_V1_00_xx, 26.10.2020 (Flow, Prosonic Flow, 0x0061)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicFlow_92_HART_FW1_01_zz_Dev_Rev_2, 26.10.2020 (Flow, Prosonic Flow, 0x0061)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Single, PRM_FF_FL_ProsonicFlow_0x1061_0x01_0x01, 18.05.2015 (Fl
ow, Prosonic Flow)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02Faceplate1.00.00Language neutral -
Prosonic Flow 92
Product Code: 92F-
Declaration Number: EC_00301_01.16EU DeclarationGerman , English , fr -
Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow B
Product Code: 92F-, 9B2B-, O9B2B-
Declaration Number: EC_00056_03.15EU DeclarationGerman , English , fr -
Prosonic Flow 92
Product Code: 92F-
EU DeclarationGerman , English , fr -
Prosonic Flow 92
Product Code: 92F-
Declaration Number: EC_00061_03.15EU DeclarationGerman , English , fr -
Prosonic Flow 92
Product Code: 92F-
Declaration Number: EC_00299_01.16EU DeclarationGerman , English , fr -
t-mass T, Prowirl R, Prowirl O, Prowirl F, T-MASS I, T-MASS F, t-mass B, t-mass A, t-mass, Prowirl D, PROSONIC FLOW P, Prosonic Flow G, PROSONIC FLOW E, Prosonic Flow 93, Prosonic Flow B, Prosonic Flow 92, Prosonic Flow 91, PICOMAG, Magphant, Dosimass, Promass 40, Promag D
Product Code: 92F-, ODMA-, 7R2B-, 7F2B-, 93P-, 93W-, 7O2B-, 7D2B-, 7O2C-, 7F2C-, 7R2C-, 65I-, 93C-, 7D2C-, 65F-, 93TA1-, 9B2B-, 9E1B-, 9EHB-, 9G3B-, 9G5B-, 9P5B-, DMA-, DTI200-, DTT31-, DTT35-, DTT35L-, DTT31L-, 91W-, 8E-, 6TAB-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 5D4C-, 40E-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EACE N RU-D.CH.AD07.B.02246/20MiscellaneousRussian -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, PROSONIC FLOW E
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-, 9E1B-, 9EHB-
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 9G5B-, 9G3B-, 93W-, 92F-, 91W-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC RU C-CH.AD07.B.01756/20MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP004 003 127MiscellaneousRussian -
Prosonic Flow 92
Product Code: 92F-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex iaExplosion Protection -
Prosonic Flow 92
Product Code: 92F-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex iaExplosion Protection -
Prosonic Flow 92
Product Code: 92F-
Region/Country: Europe (ATEX)
Approval Agency: EXAM (DMT, BVS)
Category: II 2 G, II 2(1) G
Protection: Ex d [ia], Ex iaExplosion ProtectionGerman , English -
Prosonic Flow 92
Product Code: 92F-
Region/Country: Canada
Approval Agency: CSA
Category: I/1/A,B,C,D/, II/1/E,F,G/Explosion ProtectionEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: USA
Approval Agency: FM
Protection: XPExplosion ProtectionEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: International (IECEx)
Approval Agency: EXAM (DMT, BVS)
Protection: Ex d [ia], Ex iaExplosion ProtectionEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: South Africa
Approval Agency: SABS
Category: zone 1, zone 0,1
Protection: Ex d [ia], Ex iaExplosion ProtectionEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex d [ia], Ex ia, Ex ia [ia Ga]Explosion ProtectionEnglish , Chinese -
Prosonic Flow 92
Product Code: 92F-
Region/Country: Canada
Approval Agency: CSAExplosion ProtectionEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: USA
Approval Agency: FM
Category: I/2/A,B,C,D/Txxx°C
Protection: NIExplosion ProtectionEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1
Protection: Ex d [ia]Explosion ProtectionEnglish -
Prosonic Flow 92, Prosonic Flow 93
Product Code: 92F-, 93P-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d [ia], Ex d e [ia], Ex ia, Ex ib, Ex tb [ia], Ex d [ia Gb] [ia Ga], Ex tb [ia Db] [ia Da]Explosion ProtectionRussian -
Prosonic Flow 92
Product Code: 92F-
Region/Country: Japan
Approval Agency: CML
Protection: Ex d [ia], Ex iaExplosion ProtectionEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex d [ia]Explosion Protection -
Product Family: Prosonic Flow 92
Product Code: 92F-, 92U-, 92W-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.01Fieldbus ConformanceEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: Europe
Approval Agency: Stoomwezen (LR)Pressure EquipmentEnglish -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 93P-, 93C-, 93W-, 92F-, 91W-
Region/Country: Russia (GOST)
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 48356_1MetrologyRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-
Approval Agency: RM RSMarineRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 93P-, 93C-, 93W-, 91W-, 92F-, 93TA1-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Prosonic Flow 92
Product Code: 92F-
Region/Country: International
Approval Agency: BVMarineEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: International
Approval Agency: RINAMarineEnglish -
Prosonic Flow 92
Product Code: 92F-
Region/Country: International
Approval Agency: DNVGLMarineEnglish
Accessories / Spare parts
-
-
Nr B Order code 71026978
Kit amplifier 92F HART Ex V1.00.04
-
Nr B Order code 71126042
Kit amplifier 92F HART Ex V1.01.02
-
Nr B Order code 71028092
Kit amplifier 92F Profib. PA Ex V1.00.03
-
Nr B Order code 71126044
Kit amplifier 92F Profib.PA Ex V1.01.04
-
Nr B Order code 71064584
Kit amplifier 92F Found.F. Ex V1.00.00
-
Nr B Order code 71126043
Kit amplifier 92F Found.F. Ex V1.01.04
-
-
-
Nr A Order code 71026979
Kit I/O-board 92F HART Exi
-
Nr A Order code 71026980
Kit I/O-board 92F HART/pulse Exi
-
Nr A Order code 71026981
Kit I/O-board 92F PROFIBUS PA Exi
-
Nr A Order code 71026982
Kit I/O-board 92F Found.Fieldbus Exi
-
-
-
Nr E Order code 71026984
Kit I/O-board 92F HART Exd
-
Nr E Order code 71026985
Kit I/O-board 92F HART/pulse Exd
-
Nr E Order code 71026986
Kit I/O-board 92F PROFIBUS PA Exd
-
Nr E Order code 71026987
Kit I/O-board 92F Found.Fieldbus Exd
-
-
-
Nr C Order code 50103472
Kit display 72/73/92F(HART) 12 languages
Language: EN+DE+FR+ES+IT+NL+NO+SV+ FI+PT+PL+CS
-
-
-
Nr D Order code 50103473
Kit display72/73/92F(FF/PA) 12 languages
Language: EN+DE+FR+ES+IT+NL+NO+SV+ FI+PT+PL+CS
-
-
-
Nr F Order code 71026991
Kit connec. board 92F FS elect Ex
-
-
-
Nr G Order code 71026992
Kit connec. board 92F FS sens Ex
-
-
-
Nr 25 Order code 50108141
Kit Terminal Block 72/73/92F
-
-
-
Nr 8 Order code 50103526
Kit cover 72/73/92F with window
-
-
-
Nr 9 Order code 50103527
Kit cover 23/72/73/92F blind version
-
-
-
Nr 11 Order code 50103527
Kit cover 23/72/73/92F blind version
-
-
-
Nr 12 Order code 50103527
Kit cover 23/72/73/92F blind version
-
Nr 12 Order code 71247838
Repair kit cover, remote version
Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease
-
-
-
Nr 10 Order code 50106386
-
-
-
Nr 1 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 1 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 1 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 1 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 1 Order code 50098037
Kit Cable gland Profibus PA
-
Nr 1 Order code 50098037
Kit Cable gland Profibus PA
-
Nr 1 Order code 50094984
Kit Cable gland Found. Fieldbus
-
Nr 1 Order code 50094984
Kit Cable gland Found. Fieldbus
-
-
-
Nr 3 Order code 50097147
-
-
-
Nr 4 Order code 71031256
Kit Circuit board 92F field housing
-
-
-
Nr 5 Order code 50103529
Kit Display carrier 72/73/92F field hous
-
-
-
Nr 7 Order code 71026988
Kit gaskets housing 92F FS
-
-
-
Nr 6 Order code 71026990
Kit gaskets housing 92F compact
-
-
-
Order code
Overview auxiliary equipment see spare part picture
-
Order code DK8WM-
Transmitter 80/83/84, mounting set
-
Order code XPD0036-
Prosonic Flow 92F, sensor cable set
-