Specs at a glance
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
9 dm³/min to 162 000 m³/h (2.5 gal/min to 100 000 gal/min)
-
Medium temperature range
Liner material polyamide: 0 to +60°C (+32 to +140°F)
-
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner material polyamide: 0 to +60°C (+32 to +140°F)
Electrodes: 1.4435 (316L)
Field of application
The wafer flowmeter Promag D is designed for all basic water applications where space is at a minimum. With its straightforward hard- and software design, Promag D 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology ensures measurement reliability and compliant verification.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
For basic water applications; optimized for limited space and plastic pipe installations
Device properties
Short installation length and low weight
Integrated ground disks made of stainless steel
International drinking water approvals
System integration with HART, Modbus RS485
Flexible operation with app and optional display
Benefits
-
Easy, fast centering of the sensor – innovative housing construction
-
Energy-saving flow measurement – no pressure loss due to cross section constriction
-
Maintenance-free – no moving parts
-
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
-
Simple, time-saving commissioning – guided parameterization in advance and in the field
-
Integrated verification – Heartbeat Technology
Videos
Lean selection
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Proline Promag D 10
English version - 08/2021
Electromagnetic flowmeter
EN 01/08/2021Language:
English
Version:
01/08/2021
File size:
3.6 MB
File name:
TI01603DEN_0121.pdf
-
-
-
Device Parameter (GP)
Proline Promag 10
English version - 07/2021
Electromagnetic flowmeter HART
EN 01/07/2021Language:
English
Version:
01/07/2021
File size:
1.5 MB
File name:
GP01157DEN_0121.pdf
-
-
-
Technical Information (TI)
Proline Promag D 10
Electromagnetic flowmeter
EN 01/08/2021Language:
English
Version:
01/08/2021
File size:
3.6 MB
File name:
TI01603DEN_0121.pdf
-
-
-
Operating Instruction (BA)
Proline Promag D 10
Electromagnetic flowmeter Modbus RS485
EN 01/08/2021Language:
English
Version:
01/08/2021
File size:
3.7 MB
File name:
BA02077DEN_0121.pdf
-
-
-
Operating Instruction (BA)
Proline Promag D 10
Electromagnetic flowmeter HART
EN 01/08/2021Language:
English
Version:
01/08/2021
File size:
4.4 MB
File name:
BA02076DEN_0121.pdf
-
-
-
Device Parameter (GP)
Proline Promag 10
Electromagnetic flowmeter HART
EN 01/07/2021Language:
English
Version:
01/07/2021
File size:
1.5 MB
File name:
GP01157DEN_0121.pdf
-
-
-
Device Parameter (GP)
Proline Promag 10
Electromagnetic flowmeter Modbus RS485
EN 01/07/2021Language:
English
Version:
01/07/2021
File size:
1.6 MB
File name:
GP01158DEN_0121.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 10
Modbus RS485 transmitter with electromagnetic sensor
EN 01/08/202101/07/2021Language:
English
Version:
01/08/2021
File size:
2.6 MB
File name:
KA01499DEN_0221.pdf
-
-
-
Short Instruction (KA)
Proline Promag D
Electromagnetic sensor
EN 01/08/202114/03/2017Language:
English
Version:
01/08/2021
File size:
1 MB
File name:
KA01264DEN_0221.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 10
HART transmitter with electromagnetic sensor
EN 01/07/2021Language:
English
Version:
01/07/2021
File size:
3.2 MB
File name:
KA01497DEN_0221.pdf
-
-
-
Installation Instructions (EA)
Replacing the electronics parts Exde
Proline 10
EN 04/04/202201/05/2021Language:
English
Version:
04/04/2022
File size:
1.4 MB
File name:
EA01344DA2_0222-00.pdf
-
-
-
Installation Instructions (EA)
Replacing Small parts
Promag 10, Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400, 800 Index C, Prosonic Flow E 100, Prosonic Flow E Heat, Proson ic Flow, t-mass 500-digital
EN 01/05/202101/04/202131/07/202002/08/201901/03/2018Language:
English
Version:
01/05/2021
File size:
518.1 KB
File name:
EA01119DA2_0821.pdf
-
-
Kit S+T-DAT Promag 10, Non-haz/Exd/Z2
-
Memory
Drawing numberOrder code3871505739 -
-
ISEM, standard, HART, Promag 10, nEx
-
Electronic
Drawing numberOrder code33XPD0060- -
-
ISEM, standard, Modbus, Promag 10, nEx
-
Electronic
Drawing numberOrder code33XPD0061- -
-
Kit ISEM ribbon cable, 10,Non-haz/Exd/Z2
-
Connection (electrical)
Drawing numberOrder code4671505743 -
-
ISEM,enhanced,HART,Promag 10, nEx/Z2/Exd
-
Electronic
Drawing numberOrder code33XPD0062- -
-
ISEM,enhanced,Modb.,Promag 10,nEx/Z2/Exd
-
Electronic
Drawing numberOrder code33XPD0063- -
-
Kit connection terminals, 10
-
Terminals
Drawing numberOrder code4571505745 -
-
Kit connection board,Promag D/P/W,10/500
-
Electronic (sensor)
Drawing numberOrder code4471323264 -
-
HART, 24VDC, nEx, Alu, 10
-
Electronic
Drawing numberOrder code30XPD0080- -
-
HART, 100-230VAC, nEx, Alu, 10
-
Electronic
Drawing numberOrder code30XPD0081- -
-
HART, 100-230VAC/24VDC, nEx, Alu, 10
-
Electronic
Drawing numberOrder code30XPD0082- -
-
Mbus,100-230VAC/24VDC, nEx/Exd/Z2,Alu,10
-
Electronic
Drawing numberOrder code30XPD0084- -
-
Display w/o LCD, SmartBlue app, 10
-
Display
Drawing numberOrder code50XPD0087- -
-
Display LCD, SmartBlue app, 10
-
Display
Drawing numberOrder code50XPD0088- -
-
Display LCD, touch, SmartBlue app, 10
-
Display
Drawing numberOrder code50XPD0089- -
-
Kit cover, blind ,Alu,Non-haz/ Z2/ Div.2
-
Cover
Drawing numberOrder code2171505748 -
-
Kit cover, glass,Alu,N-haz/Z2/Div.2/Exde
-
Cover
Drawing numberOrder code2071505749 -
-
Kit cover gasket, glass/blind, Alu, 10
-
Sealing
Drawing numberOrder code7071505752 -
-
Kit cover, wall mount, Alu, Ex
-
Cover
Drawing numberOrder code2371323038 -
-
Kit cover gasket, wall mount, Ex
-
Sealing
Drawing numberOrder code7571323042 -
-
Kit cover, remote, Alu
-
Cover
Drawing numberOrder code2471228796 -
-
Kit housing gaskets, remote, Alu
-
Sealing
Drawing numberOrder code7371505757 -
-
Kit interface gaskets, Alu, Promag 10
-
Sealing
Drawing numberOrder code7171505753 -
-
Kit securing clamp, screw
-
Housing/housing accessories
Drawing numberOrder code1371276494 -
-
Promag D, seal set
-
further parts
Order codeDK5DD- -
-
Spare RFID TAG
-
further parts
Order codeXPRFID- -
-
Kit weather protection cover, 10
Drawing numberOrder code8771502730 -
Pipe Mounting kit,Transmitter 10/500
Order code71346428 -
Transmitter Promag 10, 5XBBXX
Order code5XBBXX- -
Coin cell kit, Proline 10
Drawing numberOrder code49DKZ007- -
Promag D, mounting set
Order codeDKD-