Specs at a glance
-
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200 -
Measuring range
0 to 15 m/s (0 to 50 ft/s)
-
Medium temperature range
–40 to +130 °C (–40 to +266 °F)
-
Max. process pressure
N/A
Field of application
Prosonic Flow W 400 is the meter of choice for safe, cost-efficient and low-maintenance measurement of conductive and non-conductive liquids. The clamp-on mounting system and integrated web server allow for easy installation and operation. Thanks to the FlowDC option, the specified accuracy can be maintained despite disturbed flow profiles. Heartbeat Technology provides continuous transparency in your process with its diagnostic, verification and monitoring functions.
The measuring principle is non-invasive and independent of pressure, density and conductivity
Bidirectional flow measurement for water and wastewater as well as process water and hydropower plants
Device properties:
Mounting without process interruption
Wide nominal diameter range: DN 15 to 4000 (½ to 160")
Medium temperature up to +130 °C (+266 °F)
Transmitter housing made of durable polycarbonate or aluminium
Remote version for wall mounting
Integrated data logger: measured values monitoring
Benefits
Short inlet run thanks to FlowDC
Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 4000/160")
-
Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads
-
Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available
-
Safe operation – no need to open the device due to display with touch control, background lighting
-
Full remote access – web server
-
Integrated diagnostics, verification and monitoring – Heartbeat Technology
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Proline Prosonic Flow W 400
English version - 01/2022
Ultrasonic transit time flowmeter
EN 11/01/2022Language:
English
Version:
11/01/2022
File size:
3.3 MB
File name:
TI01568DEN_0121-00.pdf
-
-
-
Operating Instruction (BA)
Proline Prosonic Flow W 400
English version - 01/2022
Ultrasonic transit time flowmeter HART
EN 11/01/2022Language:
English
Version:
11/01/2022
File size:
6.3 MB
File name:
BA02086DEN_0121-00.pdf
-
-
-
Technical Information (TI)
Proline Prosonic Flow W 400
Ultrasonic transit time flowmeter
EN 11/01/2022Language:
English
Version:
11/01/2022
File size:
3.3 MB
File name:
TI01568DEN_0121-00.pdf
-
-
-
Operating Instruction (BA)
Proline Prosonic Flow W 400
Ultrasonic transit time flowmeter HART
EN 11/01/2022Language:
English
Version:
11/01/2022
File size:
6.3 MB
File name:
BA02086DEN_0121-00.pdf
-
-
-
Device Parameter (GP)
Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter HART
EN 11/01/2022Language:
English
Version:
11/01/2022
File size:
2 MB
File name:
GP01167DEN_0121-00.pdf
-
-
-
Short Instruction (KA)
Proline 400
Transmitter with ultrasonic transit time sensor HART
EN 11/01/2022Language:
English
Version:
11/01/2022
File size:
2.7 MB
File name:
KA01510DEN_0121-00.pdf
-
-
-
Short Instruction (KA)
Proline Prosonic Flow W
Ultrasonic transit time sensor
EN 11/01/2022Language:
English
Version:
11/01/2022
File size:
1.2 MB
File name:
KA01512DEN_0121-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the sensor, sensor holder, Installation set
Prosonic Flow P 500, I, W 400
EN 15/12/202101/08/2021Language:
English
Version:
15/12/2021
File size:
1.3 MB
File name:
EA01368DA2_0221-00.pdf
-
-
-
Installation Instructions (EA)
Replacing Small Parts
Promag 10, 400, 500, Promag 800 Index B, Promag 800Index C, Cubemass, Promag, Promass, Prosonic Flow, t-mass 400, 500-digital
EN 15/12/202101/05/202101/04/202101/06/202002/08/2019Language:
English
Version:
15/12/2021
File size:
1.2 MB
File name:
EA01024DA2_1121-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the Components for the Transmitter
Promag, Prosonic Flow 400, Promag 800 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
EN 15/12/202101/11/202101/04/202101/06/202002/08/2019Language:
English
Version:
15/12/2021
File size:
2 MB
File name:
EA01094DA2_1121-00.pdf
-
-
-
Installation Instructions (EA)
Pipe mounting set
Proline 400, 500-digital
EN 15/12/202131/07/202002/08/201901/02/2017Language:
English
Version:
15/12/2021
File size:
503.9 KB
File name:
EA01195DA2_0421-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the Display module
Promag 400 Index C, Prosonic Flow 400
EN 15/12/202101/06/202001/03/201807/02/2014Language:
English
Version:
15/12/2021
File size:
642.9 KB
File name:
EA01096DA2_0421-00.pdf
-