Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
With non-contact and immersion optic:
532 nm, 785 nm, 1000 nm
With bIO-Optic or Raman optic system for single use:
785 nm, 1000 nm
With bio multi optic and bio sleeve or Raman flow assembly:
785 nm
Rxn-10 probe body: 6061 aluminum, 316L stainless steel, and 303 stainless steel
Designed for product and process development, the Rxn-10 probe is trusted to deliver high-performance measurements across a wide spectral range. Compact, lightweight, and flexible, it is ideal for both solids and liquids analysis. With interchangeable optics, it adapts easily to diverse applications. Now compatible with our new KFOC1B Raman fiber-optic cable, it offers enhanced certifications and greater installation flexibility for lab and industrial environments.
Chemical: reaction monitoring, blending, catalysis, hydrocarbon speciation, process unit optimization
Polymer: polymerization reaction monitoring, polymer blending
Pharmaceutical: API reaction monitoring, crystallization
Biopharmaceutical: monitoring, optimization, and control of cell culture, fermentation, and downstream applications
Food & Beverage: zonal heterogeneity mapping of meats and fish
Multipurpose use for both solids and liquids measurement
Lightweight and compact
Integrated laser safety interlock, including “laser on” indication and probe shutter
Flexible output compatible with a range of sampling options
Easy switching of non-contact, immersion, and bioprocessing optics to suit a variety of applications
Wide spectral range, including access to the critical low-wavenumber region
Upgraded, Communications Multipurpose Riser (CMR)-certified KFOC1B Raman fiber-optic cable option for improved fire resistance, simplified regulatory compliance, and enhanced flexibility for easier routing and handling
High-end products
Technical excellence
Simplicity
Standard products
Technical excellence
Simplicity
Specialized products
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Rxn-10探头光学器件的系统设计和规格参数:拉曼浸入式光学器件(KIO1)、
非接触式光学器件(KNCO1)、生物工艺用光学器件(KLBIO1)、
生物工艺用多重光学器件(KRBMO)、生物工艺用套管(KRBSL)以及一次性拉曼光学系统(KRSU1)
| EN | |||
|
31/03/2025
|
|
|
|
|
Language: |
Chinese |
|
Version: |
31/03/2025 |
|
File size: |
698.9 KB |
|
File name: |
TI01635CZH_0322.pdf |
System design and specifications for the Raman Rxn-10 probe
| EN | |||
|
08/09/2025
|
|
|
|
|
13/11/2024
|
|
|
|
|
31/05/2023
|
|
|
|
Language: |
English |
|
Version: |
08/09/2025 |
|
File size: |
949 KB |
|
File name: |
TI01629CEN_0525.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1), and
Raman optic system for single use (KRSU1)
| EN | |||
|
03/08/2022
|
|
|
|
Language: |
English |
|
Version: |
03/08/2022 |
|
File size: |
1.2 MB |
|
File name: |
BA02171CEN_0222.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
| EN | |||
|
08/09/2025
|
|
|
|
|
02/12/2024
|
|
|
|
Language: |
English |
|
Version: |
08/09/2025 |
|
File size: |
1.8 MB |
|
File name: |
BA02160CEN_0525.pdf |
Raman Rxn-10 プローブのクイックスタートガイド
| EN | |||
|
17/04/2025
|
|
|
|
|
Language: |
Japanese |
|
Version: |
17/04/2025 |
|
File size: |
2.2 MB |
|
File name: |
KA01546CJA_0424.pdf |
Graphic illustrating the core elements of Biopharma 4.0 including
product lifecycle stages, role of PAT/QbD, and 12 key advanced
technologies for scientists and process engineers in the Life
Sciences, applicable to Raman spectroscopy systems (Raman
Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and
sleeve, flow cell and flow bench, Raman optic system for single
use, and Raman calibration & verification kits).
|
Language: |
English |
|
Version: |
22/05/2025 |
|
File size: |
481.6 KB |
|
File name: |
PU01614CEN_0125.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Language: |
English |
|
Version: |
26/06/2025 |
|
File size: |
363.4 KB |
|
File name: |
PU01611CEN_0125.pdf |
An overview of the Raman flow assembly (flow bench and flow cell)
used with the Rxn-10 probe in conjunction with a Raman Rxn2
analyzer and a Raman flow assembly calibration and verification kit
for downstream bioprocessing (powered by Kaiser Raman technology).
|
Language: |
English |
|
Version: |
31/05/2023 |
|
File size: |
837 KB |
|
File name: |
PU01517CEN_0123.pdf |
Endress+Hauserが、ライフサイエンス分野の専門知識と、ラマン分
光システム(Raman Rxn2、Raman Rxn4、Rxn-10、Rxn-45、Rxn-46、
バイオマルチオプティックおよびスリーブ、フローフィル、フロー
ベンチ、シングルユース用Ramanオプティックシステム)や水質分
析センサ技術(Liquiline CM44P、CM442、OUSAF44、OUSBT66、
Memosens CPS61E、CLS82E、COS81E、CLS82E)などの信頼性の高い
インラインおよびリアルタイム測定技術によって、世界トップクラ
スのバイオ医薬品メーカーから信頼されている理由を強調したグラ
フィック。
|
Language: |
Japanese |
|
Version: |
04/10/2024 |
|
File size: |
2.5 MB |
|
File name: |
PU01585CJA_0124_Graphic_EH biopharma trust.pdf |
Ein Leitfaden zu unseren Anwendungshinweisen zur
Raman-Spektroskopie für die Life-Science-Industrie
(Raman Rxn2-Analysator, Raman Rxn4-Analysator,
Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde,
Rxn-46-Sonde und Zubehör für Sondenoptiken
(blO-Optic, Raman- Single Use-Optiksystem
/ SUB, Immersionsoptik, berührungslose Optik)
|
Language: |
German |
|
Version: |
24/09/2025 |
|
File size: |
1.4 MB |
|
File name: |
PU01447CDE_0222_Raman-Anwendungsleitfaden_LSI_web.pdf |