Pressure measurement
Powerful instruments for process pressure, differential pressure, level and flow
F
L
E
X
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Compare
Accuracy
Standard 0.2% Optional 0.1%
Process temperature
-10°C...100°C (14°F...212°F)
Pressure measuring range
100 mbar...10 bar (1.5 psi...150 psi)
Process pressure / max. overpressure limit
40 bar (600 psi)
Main wetted parts
Alloy C 316L optional coating AuPt
Max. measurement distance
100m (328ft) H2O
Material process membrane
316L, AlloyC Gold-Rhodium
Measuring cell
100 mbar...10 bar (1.5 psi...150 psi)
Accuracy
Standard 0.2% Optional 0.1%
Process temperature
-10°C...85°C (14°F…212°F)
Pressure measuring range
100 mbar...10 bar (1.5 psi...150 psi)
Process pressure / max. overpressure limit
40 bar (600 psi)
Main wetted parts
Alloy C 316L optional coating AuPt
Max. measurement distance
100m (328ft) H2O
Material process membrane
316L, AlloyC Gold-Rhodium
Measuring cell
100 mbar...10 bar (1.5 psi...150 psi)
Accuracy
Standard 0.2% Optional 0.1%
Process temperature
PE cable: -10°C…70°C / 14°F…158°F FEP cable: -10°C…80°C / 14°F…176°F
Pressure measuring range
100 mbar...10 bar (1.5 psi...150 psi)
Process pressure / max. overpressure limit
40 bar (600 psi)
Main wetted parts
Alloy C 316L Cable (PE/FEP) optional coating AuPt optional coating AuRh
Max. measurement distance
100 m (328 ft) H2O
Material process membrane
316L, AlloyC, Gold-Rhodium PE, FEP
Measuring cell
100 mbar...10 bar (1.5 psi...150 psi)
Accuracy
Standard 0.2% Optional 0.1%
Process temperature
PE cable: -10°C…70°C / 14°F…158°F FEP cable: -10°C…80°C / 14°F…176°F
Pressure measuring range
100mbar...10bar (1.5psi...150psi)
Process pressure / max. overpressure limit
40 bar (600 psi)
Main wetted parts
Alloy C 316L Cable (PE/FEP) optional coating AuPt optional coating AuRh
Max. measurement distance
100 m (328 ft) H2O
Material process membrane
316L, AlloyC, Gold-Rhodium PE, FEP
Measuring cell
100 mbar...10 bar (1.5 psi...150 psi)
Accuracy
Standard 0.1% Optional 0.075%
Process temperature
-10°C...+100°C (+14°F...+212°F)
Pressure measuring range
100 mbar...10 bar (1.5 psi...150 psi)
Process pressure / max. overpressure limit
40 bar (600 psi)
Main wetted parts
Alloy C 316L
Max. measurement distance
100 m (328 ft) H2O
Material process membrane
316L, AlloyC, Gold-Rhodium
Measuring cell
100 mbar...10 bar (1.5 psi...150 psi)
Accuracy
0.075% of individual sensor, "PLATINUM" 0.05% of individual sensor
Process temperature
–25...+150°C (–13...+302°F)
Pressure measuring range
100mbar...40bar (1.5psi...600psi)
Process pressure / max. overpressure limit
60 bar (900 psi)
Material process membrane
Ceramic 316L, AlloyC
Measuring cell
100 mbar...40 bar (1.5 psi...600 psi)
Accuracy
0.075% of individual sensor, "PLATINUM" 0.05% of individual sensor
Process temperature
–40...+125°C (–40 ... +257°F)
Pressure measuring range
400 mbar...10 bar (6 psi...150 psi)
Process pressure / max. overpressure limit
160 bar (2400 psi)
Main wetted parts
316L, Alloy C
Material process membrane
316L, AlloyC,
Measuring cell
400 mbar...10 bar (6 psi...150psi)
Phase out - View Successors
Back
Product is getting phased out
New alternatives available
Phase out policy
Endress+Hauser are committed to the long term support of all our products
We undertake support and service for our products for a period of ten years after notice of product withdrawal (until spareparts are not available any more)
However we reserve us the right to offer alternative solutions including replacement products if deemed more appropriated.
Product status
Product root
FMD77
Name
Differential pressure
Deltabar FMD77
Product status
In phase out
Phase out date
12/2024
Order stop
6/2027
Spare sensor until
not applicable
Calibration until
not applicable
Spares available
7/2030
Repair until
7/2030
Maintenance advice
Compare
Accuracy
0,075% + influence of diaphragm seal
Process temperature
-40°C...400°C (-40°F...752°F)
Pressure measuring range
100mbar...16bar (1.5psi...230 psi)
Process pressure / max. overpressure limit
160bar (2400 psi)
Main wetted parts
Alloy C276 316L Monel Tantalum
Max. measurement distance
160m (525ft) H2O
Material process membrane
316L, AlloyC, Tantal, Gold-Rhodium, PTFE
Measuring cell
100 mbar...16 bar (40 inH20...240 psi)
Phase out - View Successors
Back
Product is getting phased out
New alternatives available
Phase out policy
Endress+Hauser are committed to the long term support of all our products
We undertake support and service for our products for a period of ten years after notice of product withdrawal (until spareparts are not available any more)
However we reserve us the right to offer alternative solutions including replacement products if deemed more appropriated.
Product status
Product root
FMD78
Name
Differential pressure
Deltabar FMD78
Product status
In phase out
Phase out date
12/2024
Order stop
6/2027
Spare sensor until
not applicable
Calibration until
not applicable
Spares available
7/2030
Repair until
7/2030
Maintenance advice
Compare
Accuracy
0,075% + influence of diaphragm seal
Process temperature
-40°C...400°C (-40°F...752°F)
Pressure measuring range
100mbar...40bar (1.5psi ... 600 psi)
Process pressure / max. overpressure limit
160bar (2400 psi)
Main wetted parts
Alloy C276 316L Monel Tantalum
Max. measurement distance
400m (1312ft) H2O
Material process membrane
316L, AlloyC, Tantal, Gold-Rhodium PTFE
Measuring cell
100 mbar...40 bar (40 inH2O...600 psi)
Accuracy
pn ≥ 400mbar: 0.35 % pn < 400mbar: 0.50 %
Process temperature
-10°C...+70°C (+14°F...+158°F)
Pressure measuring range
200 mbar...2 bar (3 psi...29 psi)
Process pressure / max. overpressure limit
10 bar (145 psi)
Main wetted parts
316L
Max. measurement distance
20 m H2O (66 ft H2O)
Material process membrane
Metal
Measuring cell
200 mbar...2 bar (3 psi...29 psi)
Do you need help selecting and sizing your next device?
Comfortably select, size and configure best-fit products for your measuring tasks and application.
About pressure measurement
Whether pressure, level or flow, today pressure measurement technology is often used for measuring liquids, pastes and gases. With a wide range of sensor technology Endress+Hauser offer instruments with perfect fit for any kind of application.
Particularly small, exceptionally powerful: the Compact Line
The Compact Line offers high performance in a compact design. The product portfolio includes the Micropilot FMR43 , a compact radar device for non-contact level measurements with either 80 GHz or 180 GHz, as well as the proven-in-use point level sensor Liquiphant FTL43 and a reliable Cerabar PMP43 for pressure and hydrostatic level measurement. Specifically designed to meet the requirements in hygienic applications, our solutions increase the productivity, safety and simplicity of processes.
Downloads
Explore additional resources
Pressure Measurement Overview brochure
Products and services of our pressure measuring technologies at a glance
Download
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all