Specs at a glance
-
Measurement range
pH 0-14
-
Process temperature
max. 110°C
(230°F) -
Process pressure
max. 10 bar
(145 psi)
Field of application
Memosens CPS96D is the expert for fibrous media or media with a high content of suspended solids such as dispersions, precipitation or emulsions. The open aperture guarantees the most reliable, simultaneous pH and ORP measurement for better process control and increased quality. Memosens CPS96D is not the latest Memosens generation. To get information on the new Memosens CPS96E sensor with extended functionality, click here.
Chemical processes
Pulp and paper industry
Contaminated media and suspended solids
- Dispersions
- Precipitation
- Emulsions
With ATEX and IEC approval for use in hazardous areas.
Benefits
Simultaneous measurement of pH, ORP and rH values (in rH mode) for a better process overview
Additional platinum electrode enables constant monitoring of reference impedance and thus sensor quality
Robust and resistant to poisoning thanks to stabilized gel and reference with ion trap
Not affected by fluctuations in pressure and temperature
Maximum process safety through non-contact inductive signal transmission
Enables predictive maintenance due to storage of sensor and process-specific data
Reduced operating costs due to minimized process downtime and extended sensor lifetime
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Memosens CPS96D Technical Information
Combination of pH and ORP electrode with Memosens technology
EN 30/11/201402/05/2012Language:
English
Version:
30/11/2014
File size:
404.1 KB
File name:
TI00507CEN_0214.pdf
-
-
-
Operating Instruction (BA)
Memosens CPS16D/76D/96D Operating Instructions
Combined pH and ORP electrodes with Memosens technology Kombination aus pH- und Redoxelektrode mit Memosens-Technologie
EN 31/01/201822/05/2012Language:
English
Version:
31/01/2018
File size:
697 KB
File name:
BA01109CA2_0218.pdf
-
-
-
Ex Safety Instruction (XA)
Memosens pH/ORP Sicherheitshinweise für elektrische Betriebsmittel im explosionsgefährdeten Bereich Safetyinstructions for electrical apparatus for explosion-hazardous areas Conseils de sécurité pour matériels électriques destinés aux zones explosibles Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN 22/02/201604/03/201514/01/201321/10/201001/12/2006Language:
English
Version:
22/02/2016
File size:
4.3 MB
File name:
XA00376CA3_1616.pdf
-
-
-
Ex Safety Instruction (XA)
Memosens pH/ORP Sicherheitshinweise für elektrische Betriebsmittel im explosionsgefährdeten Bereich Safetyinstructions for electrical apparatus for explosion-hazardous areas Conseils de sécurité pour matériels électriques destinés aux zones explosibles Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN 11/11/201631/12/201101/04/2009Language:
English
Version:
11/11/2016
File size:
3.7 MB
File name:
XA00079CA3_1416.pdf
-
-
-
Ex Safety Instruction (XA)
Memosens pH/ORP sensors
pH and ORP measurement Supplement to: BA01572C, BA01109C Safety instructions for electrical equipment in explosion-hazardous areas EAC Ex 0Ex ia IIC T3/T4/T6 Ga X EAC Ex 0Ex iaIIC T4/T6 Ga X
EN 01/03/202218/02/202108/03/2016Language:
English
Version:
01/03/2022
File size:
508.1 KB
File name:
XA01437CEN_0322-00.pdf
-
-
-
Ex Safety Instruction (XA)
Memosens ph/ORP sensors
pH/ORP measurement Supplement to BA01572C, BA01109C Safety instructions for electrical apparatus in explosion-hazardous areas UKEx II 1 G Ex ia IIC T3/T4/T6 Ga UK Ex II 1 G Ex ia IIC T4/T6 Ga
Language:
English
Version:
08/12/2021
File size:
435.2 KB
File name:
XA02786CEN_0121-00.pdf
-
-
-
Competence Brochure (CP)
pH-Messung in Industrieprozessen
Auswahl- und Engineering-Hilfe für verschiedene Industriebranchen und Applikationen
Language:
German
Version:
25/03/2020
File size:
3.3 MB
File name:
CP00010CDE_1520_pH-Auswahlhilfe20.pdf
-
-
-
Competence Brochure (CP)
pH measurement in industrial processes
Selection and engineering guide for different industries and applications
Language:
English
Version:
24/02/2020
File size:
3.3 MB
File name:
CP00010CEN_1520_pH-selection-guide20.pdf
-
-
-
White paper (WP)
Damit bei der pH-Messung höchste Genauigkeit garantiert ist
Kalibrierung,Justierung und Verifizierung
Language:
German
Version:
07/04/2021
File size:
605.2 KB
File name:
WP01154C07DE_01.21_Damit bei der pH-Messung hoechste Genauigkeit garantiert ist.pdf
-
-
-
White paper (WP)
Ensuring maximum accuracy in pH measurement
Calibration, adjustment and verification
Language:
English
Version:
07/04/2021
File size:
600 KB
File name:
WP01154C07EN_01.21_Ensuring maximum accuracy in pH measurement.pdf
-