Specs at a glance
-
Max. measurement error
Density: ±0.01g/cm³
Temperature: ±0.5K
Sound velocity: 2m/s -
Measuring range
Concentration According to concentration app data sheet, maximum 0 to 100 %
Sound velocity 600 to 2000 m/s
Temperature concentration app data sheet, maximum 0 to +100 °C (32 to +212 °F)
Density 0.7 to 1.5 g/cm³ -
Measuring range
Concentration According to concentration app data sheet, maximum 0 to 100 %
Sound velocity 600 to 2000 m/s
Temperature concentration app data sheet, maximum 0 to +100 °C (32 to +212 °F)
Density 0.7 to 1.5 g/cm³ -
Medium temperature range
0 to 120°C (32 to 248 °F)
-
Process temperature
0 to 120°C (32 to 248 °F)
-
Max. process pressure
max. 16 bar at 20 °C (232 psi at 68 °F)
-
Process pressure
max. 16 bar at 20 °C (232 psi at 68 °F)
Field of application
Teqwave H is ideal for real-time liquid analysis in hygienic applications like spirits and soft drink production. End customers and equipment manufacturers value its highly accurate in situ concentration measurement and hygienic design. Teqwave reduces the operational expenditure by monitoring various measuring parameters at once. Match your Teqwave transmitter perfectly to your production needs by flexible definition and extension of your application range.
The acoustic waveguide measures precisely and reliably, even the smallest changes are detected
Continuous quality monitoring of beverages and in cleaning processes
Device properties
Nominal diameter: DN 25 (1")
Sensor housing made of stainless steel (3-A, EHEDG)
Accurate and independent of flow profile
Industry-compliant, easy installation via DIN rail and pipe mounting set
3.5" TFT color touch screen or LED indication
4-20 mA, Modbus TCP
Benefits
High accuracy and repeatability – concentration calculation with latest algorithms
Fulfilment of hygienic requirements – easily cleanable full-bore sensor
Full transparency – constant monitoring of product quality without sampling
Highest process safety – reliable metering due to robust, maintenance-free sensor
Customized usage – innovative application concept, expendable for changing measuring tasks
Simplified process control – user-friendly operation and clear status visualization
Local data backup – integrated data storage for measured values up to 7,5 years
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Teqwave H
Ultrasonic concentrationmeter
EN 04/02/202201/04/2021Language:
English
Version:
04/02/2022
File size:
2 MB
File name:
TI01573DEN_0221-00.pdf
-
-
-
Operating Instruction (BA)
Teqwave H
Ultrasonic concentrationmeter
Modbus TCPEN 04/02/202201/04/2021Language:
English
Version:
04/02/2022
File size:
2.5 MB
File name:
BA02084DEN_0221-00.pdf
-
-
-
Short Instruction (KA)
Teqwave H
Ultrasonic concentrationmeter
EN 04/02/202201/04/2021Language:
English
Version:
04/02/2022
File size:
2.1 MB
File name:
KA01501DEN_0221-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the connection cable
Teqwave F, I, T, H
EN 26/03/202101/12/2017Language:
English
Version:
26/03/2021
File size:
526.9 KB
File name:
EA01229DA2_0221.pdf
-
-
-
Installation Instructions (EA)
Installing mounting set and seal
Teqwave H
EN 26/03/2021Language:
English
Version:
26/03/2021
File size:
438.9 KB
File name:
EA01316DA2_0121.pdf
-
-
-
Special Documentation (SD)
UKCA marking
Flow, density, concentration, viscosity
EN 04/11/202201/10/2021Language:
English
Version:
04/11/2022
File size:
357.4 KB
File name:
SD02752DEN_0222-00.pdf
-
-
-
Special Documentation (SD)
SD Teqwave
EAC Special Documentation
Language:
English
Version:
17/09/2024
File size:
857.2 KB
File name:
SD03317DEN_0124-00.pdf
-
-
-
Special Documentation (SD)
Concentration App Questionaire
Concentration App
QuestionaireEN 12/09/202421/06/202229/05/201905/03/201819/12/2017Language:
English
Version:
12/09/2024
File size:
463.8 KB
File name:
SD02148DEN_0524.pdf
-
-
-
Case Study (CS)
Kontinuierliche Brix-Messung von Softdrinks
Teqwave H löst manuelle Refraktometermessung bei Kreuzberg Quelle ab
Language:
German
Version:
01/05/2022
File size:
2.2 MB
File name:
CS01734D06DE0122_Kreuzberg-Quelle.pdf
-
-
-
Case Study (CS)
Continuous Brix measurement of soft drinks
Teqwave H replaces manual refractometer measurement at Kreuzberg Quelle
Language:
English
Version:
01/05/2022
File size:
2.2 MB
File name:
CS01734D06EN0122_Kreuzberg-Quelle.pdf
-