Výrobek není dostupný na českém trhu.
Souhrn technické specifikace
-
Spectral coverage
Base Model and Enclosure configuration:
150-4350 cm-1 (532 nm)
150-3425 cm-1 (785 nm)
200-2400 cm-1 (1000 nm)
Hybrid: 175-1890 cm-1 (785 nm)
Oblast použití
The Raman Rxn4 analyzer powered by Kaiser Raman technology is the optimal choice for manufacturing or process environments. Raman Rxn4 provides high-resolution performance for in situ, real-time measurement and control. It features unique self-monitoring, diagnostics, and self-calibration to ensure the validity of each measurement. Stackable in a standard 19" rack, the Raman Rxn4 saves valuable space on the production floor. It is also offered with an optional stainless steel NEMA 4X enclosure.
Chemical: reaction monitoring, blending, catalysis investigations
Polymer: polymerization reaction monitoring, extrusion monitoring, polymer blending
Pharmaceutical: API reaction monitoring, crystallization, polymorph
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: Mapping of meats and fish, fermentation, reaction monitoring
Oil & Gas: LNG, refining, energy measurements
Výhody
Robust, reliable, and highly accurate
Easy installation and minimal maintenance/downtime
24/7 inline, online, or at-line process measurement and monitoring
Unified internal construction enables straightforward model transfer to support redundant analyzer systems
Intuitive, fully embedded Raman RunTime control software via touchscreen or remote interface
Scale-up, scale-out, and cGMP/pilot-plant compatible
Suitable for outputs into hazardous area/classified environments
Výběr produktů z řady Extended
-
Špičkové produkty
- Vysoce funkční a přesto jednoduché
Technická výkonnost
Jednoduchost
-
Jednoduché produkty
- Jednoduchý výběr, instalace i provoz
Technická výkonnost
Jednoduchost
-
Standardní produkty
- Spolehlivé, robustní a nenáročné na údržbu
Technická výkonnost
Jednoduchost
-
Špičkové produkty
- Vysoce funkční a přesto jednoduché
Technická výkonnost
Jednoduchost
-
Specializované produkty
- Navrženo pro těžké aplikace
Technická výkonnost
Jednoduchost
Dle konkrétního produktu
Výběr produktů FLEX | Technická výkonnost | Jednoduchost |
---|---|---|
Výběr produktů z řady Fundamental Pro jednoduché aplikace |
Technická výkonnost
|
Jednoduchost
|
Výběr produktů z řady Lean Efektivně pokrývejte běžné procesní požadavky |
Technická výkonnost
|
Jednoduchost
|
Výběr produktů z řady Extended Optimalizujte své procesy inovativními technologiemi |
Technická výkonnost
|
Jednoduchost
|
Výběr produktů z řady Xpert Zvládněte i ty nejtěžší aplikace |
Technická výkonnost
|
Jednoduchost
Dle konkrétního produktu |
-
-
Technické informace (TI)
Raman Rxn4 Technical Information
System design and specifications for the Raman Rxn4 analyzer -
powered by Kaiser Raman technologyJazyk:
English
Verze:
21/11/2023
Velikost souboru:
1.1 MB
Název souboru:
TI01645CEN_0323.pdf
-
-
-
Návod k obsluze (BA)
Raman RunTime v6.5 Operating Instructions
Commissioning, operation, and maintenance details
for Raman RunTime v6.5 softwareEN CS 16/11/202316/11/202231/12/2020Jazyk:
English
Verze:
16/11/2023
Velikost souboru:
6.7 MB
Název souboru:
BA02180CEN_0423.pdf
-
-
-
Návod k obsluze (BA)
Raman Rxn4 Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn4 analyzer - powered by Kaiser Raman technologyJazyk:
English
Verze:
27/03/2024
Velikost souboru:
9 MB
Název souboru:
BA02178CEN_0424.pdf
-
-
-
Krátká instrukce (KA)
Raman Rxn4 Brief Operating Instructions
Quick start guide for the Raman Rxn4 analyzer -
powered by Kaiser Raman technologyJazyk:
English
Verze:
21/11/2023
Velikost souboru:
2.5 MB
Název souboru:
KA01553CEN_0222.pdf
-
-
-
Návod k instalaci (EA)
LNG analyzer performance verification kit Installation Instructions
Instructions for use of the LNG analyzer performance verification kit
Jazyk:
English
Verze:
30/03/2023
Velikost souboru:
442.7 KB
Název souboru:
EA01470CEN_0123.pdf
-
-
-
Ex bezpečnostní pokyny (XA)
Raman Rxn4 Safety Instructions
Hazardous area certifications and installation instructions
for the Raman Rxn4 analyzer - powered by Kaiser Raman technologyJazyk:
English
Verze:
07/12/2023
Velikost souboru:
1.1 MB
Název souboru:
XA02745CEN_0323.pdf
-
-
-
PU (publikace)
Raman analyzer application guide for the oil & gas and chemical industries - Composition analysis of gas streams and LNG
A guide to our Raman spectroscopy analyzer and probe portfolio,
powered by Kaiser Raman technology, for composition analysis of
gas streams and LNG (includes the Raman Rxn4 analyzer, the
Raman Rxn5 analyzer, the Raman Rxn-30 probe, and
Raman Rxn-41 probe) in the chemical industry and oil & gas industry.Jazyk:
English
Verze:
08/12/2021
Velikost souboru:
2.5 MB
Název souboru:
PU01445CEN_0121.pdf
-
-
-
PU (publikace)
Kaiser Raman technology and Sartorius BioPAT Spectro® collaboration Q&A - Scalable, real-time bioprocess monitoring solutions
A Q&A about how our Raman spectroscopy analyzer systems
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
and Rxn-46 probe), powered by Kaiser Raman technology, integrates
with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for
high throughput and single use (SUB) bioprocessingin the
biopharmaceutical life science industry.Jazyk:
English
Verze:
08/12/2021
Velikost souboru:
943.7 KB
Název souboru:
PU01446CEN_0121.pdf
-
-
-
PU (publikace)
Advanced process and product control in fermentations - Raman spectroscopy for composition analysis in a lab or process
An overview of Raman spectroscopy analyzer systems (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, and Rxn-45
probe), powered by Kaiser Raman technology, for fermentation
compositional analysis in a lab or process applicable to biotechnology
in the food & beverage industry.Jazyk:
English
Verze:
03/03/2022
Velikost souboru:
603 KB
Název souboru:
PU01457CEN_0122.pdf
-
-
-
PU (publikace)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).Jazyk:
English
Verze:
19/04/2022
Velikost souboru:
1.1 MB
Název souboru:
PU01447CEN_0222.pdf
-
-
-
PU (publikace)
Industry standards on gas quality - Raman Rxn5 analyzer (syngas/LNG) andRaman Rxn4 analyzer (LNG)
A list of industry gas quality standards that our Raman Rxn5
analyzer meets for syngas / LNG and our Raman Rxn4
analyzer meets for LNG.Jazyk:
English
Verze:
20/04/2022
Velikost souboru:
432.5 KB
Název souboru:
PU01463CEN_0122.pdf
-
-
-
PU (publikace)
Raman calibration and verification kits - Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability
An overview of the Raman calibration and verification kits for
the bio multi optic / single use optic and the Raman flow assembly
(includes the flow bench and flow cell). These kits are to be used in
conjunction with the Rxn-10 probe and Raman Rxn2 / Rxn4 analyzer
for upstream and downstream bioprocessing (powered by Kaiser
Raman technology).Jazyk:
English
Verze:
13/12/2023
Velikost souboru:
2.1 MB
Název souboru:
PU01518CEN_0223.pdf
-
-
-
PU (publikace)
Raman Rxn4 analyzer - LNG custody transfer analyzer
An overview brochure about the Raman Rxn4 analyzer,
a Raman spectroscopy analyzer powered by Kaiser Raman
technology for LNG custody transfer in the Oil & Gas industry.Jazyk:
English
Verze:
20/01/2022
Velikost souboru:
492.1 KB
Název souboru:
PU01451CEN_0122.pdf
-
-
-
PU (publikace)
Energy transition - Our gas analyzers are ready
An overview of energy transition and the importance of gas analysis
via TDLAS, QF, and Raman spectroscopy (including the J22, OXY5500,
Raman Rxn4, and Raman Rxn5 analyzers) to meet the demand for an
energy supply chain shift away from carbon toward renewable energy,
natural gas, hydrogen, LNG, biogas and more in the oil & gas industry.Jazyk:
English
Verze:
03/03/2022
Velikost souboru:
2.3 MB
Název souboru:
PU01458CEN_0122.pdf
-
-
-
PU (publikace)
Lab-to-process monitoring & control in Life Sciences - Reliable measurement of bioprocess physical and chemical properties
A combined product list of analysis offerings from both Optical Analysis
and LIquid Analysis for bioprocessing applications in the life science
industry (including Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Rxn-10 probe, bio multi optic and bio sleeve, Raman flow assembly,
Rxn-45 probe, Rxn-46 probe, Raman optic system for single use,
Memosens CPS61E, Memosens COS81E, OUSBT66, Memosens CPS61E,
Memosens CPS77E, Memosens CLS82E, OUSAF44, Memosens CPS11E,
Memosens CLS16E, TOC Analyzer CA79, Liquiline transmitter platform, and
Memobase software).Jazyk:
English
Verze:
11/04/2024
Velikost souboru:
776.1 KB
Název souboru:
PU01484CEN_0224.pdf
-
-
-
Kompetenční brožura (CP)
Raman spectroscopy food & beverage application guide - Trusted technology for composition analysis in a laboratory or process environment
A guide to Raman spectroscopy application notes for the
food & beverage industry (featuring studies using the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-20 probe, Rxn-45 probe, and the immersion optic
and non-contact optic).Jazyk:
English
Verze:
17/02/2022
Velikost souboru:
859 KB
Název souboru:
CP01489CEN_0122.pdf
-
-
-
Případová studie (CS)
Optimizing carbon capture processes through Raman spectroscopy
This case study examines how USN used Raman spectroscopy,
including a Raman Rxn2 analyzer and a Rxn-40probe, to monitor
CO2 capture solvent quality in the chemical industry (note: this
application would also work with a Raman Rxn4 analyzer / the
oil & gas industry).Jazyk:
English
Verze:
31/01/2022
Velikost souboru:
876.1 KB
Název souboru:
CS01714CEN_0222.pdf
-
-
-
Inovace (IN)
Raman technology in bioprocessing - Scalable in situ bioprocess monitoring enabling advanced process control
An overview brochure about our Raman spectroscopy analyzer
and probe portfolio, powered by Kaiser Raman technology, for
the bioprocessing / biopharmaceutical industry (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic,
Raman single use optic system, bio multi optic with bio sleeve, and
Raman flow assembly), powered by Kaiser Raman technology.Jazyk:
English
Verze:
19/06/2023
Velikost souboru:
6.8 MB
Název souboru:
IN01228CEN_0223.pdf
-
-
-
Inovace (IN)
Raman technology for the chemical industry - Reliable composition measurement of chemical process streams
An overview brochure about our Raman spectroscopy analyzer systems,
powered by Kaiser Raman technology, for the chemical industry
(includes the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Raman Rxn5 analyzer, and the Raman Rxn-10 probe, Raman Rxn-20 probe,
Raman Rxn-30 probe, Raman Rxn-40 probe, and Raman Rxn-41 probe).Jazyk:
English
Verze:
18/10/2021
Velikost souboru:
10.6 MB
Název souboru:
IN01223CEN_0121.pdf
-
-
-
Inovace (IN)
Raman spectroscopic analyzers - Robust optical measurement of chemical composition
An overview brochure about our Raman Rxn2 analyzer and Raman Rxn4
analyzer systems (including starter and hybrid variant analyzer
configurations), a suite of Endress+Hauser Raman spectroscopy analyzers
powered by Kaiser Raman technology.Jazyk:
English
Verze:
18/10/2021
Velikost souboru:
4 MB
Název souboru:
IN01221CEN_0121.pdf
-