Micropilot M FMR250

Tento produkt již není k dispozici.

Vyhledejte prosím novou generaci v části předcházející/navazující produkt nebo kontaktujte svou místní pobočku Endress+Hauser.

Technické informace

Zpět

Details

  • Měřicí princip

    Radarový hladinoměr pevných látek

  • Charakteristika/aplikace

    Non-contact level measurement especially in powdery to granular bulk solids. Level measurement in tall silos with extremely dusty bulk solids e.g. cement, raw meal or animal feed. Applications with highly abrasive bulk solids e.g. ferrite / clinker

  • Speciální produkty

    Air purge connection

  • Dodávka/komunikace

    2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)

  • Kmitočet

    K-Band (~ 26 GHz )

  • Anténa

    Parabolic DN200/8", DN250/10"

    Horn DN80/3", DN100/4"

  • Přesnost

    +/- 15mm (or 0.04% of range, whatever is larger)

  • Okolní teplota

    -40 °C...+80 °C
    (-40 °F...+176 °F)

  • Procesní teplota

    -40 °C...+200 °C
    (-40 °F...+392 °F)

  • Procesní tlak absolutní / max. mez přetlaku

    Vacuum...16bar
    (Vaccum...232psi)

  • Hlavní smáčené díly

    PEEK, 1.4435, 1.4404, 316L

  • Procesní připojení

    Thread:

    R1 1/2", NPT1 1/2

    Flange:

    DN80, DN 100

    ASME 3", 4"

    JIS 80A, 100A

    UNI DN100/4"...DN250/10"

  • Blokovací vzdálenost

    Antenna length + 400mm (15.75")

  • Max. měřená vzdálenost

    70 m (230 ft)

  • Komunikace

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certifikáty/schválení

    ATEX, FM, CSA, NEPSI

    SIL

  • Volitelné možnosti

    Separate display
    Antenna extension 250 mm/ 10" or 450 mm/18"
    Top Target Positioner (+/-15°)

  • Meze aplikace

    Dk < 1.6

    Reduction of the max. possible measuring range through:

    Media with poor reflection properties

    Angle of repose

    Extremely loose surfaces of bulk solids, e.g. bulk solids with low bulk weight for pneumatic filling

    Build-up, above all of moist products

Dokumenty / software

Příslušenství / náhradní díly

Nr
Order code
Specification
    • Order code 52006628

      Instrument plug M20-M12 "PA" (WDM)150

      4-pin metall plug for installation in the device, providing connection to a T-Box (WDM) or cable socket (WDM). Cable length: 150mm. Not suitable for PROMAG and PROMAG.

  • 12
    • Nr 12 Order code 535720-9020

      Set of screws housing F12/T12/F23

      Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.

  • 20
    • Nr 20 Order code 517391-0011

      Cover F12/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.

  • 25
    • Nr 25 Order code 518710-0020

      Cover T3/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.

  • 20
    • Nr 20 Order code 52005936

      Cover F12/T12 Alu, window, gasket

      Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.

  • 11
  • 20
  • 11
  • 35
    • Nr 35 Order code 52006197

      Terminal module 4-pole, HART, 2-wire

      Cable connection. Usage: housing F12/F23, Micropilot M, Levelflex M, Prosonic M.

    • Nr 35 Order code 52012156

      Terminal module 4-pole, PA, FF

      PROFIBUS PA, FOUNDATION Fieldbus. Usage: Micropilot II/M, Prosonic M, Levelflex M.

    • Nr 35 Order code 52013302

      Terminal mod. Ex d, 4-pol., 2wr,HART,T12

      Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.

    • Nr 35 Order code 52013303

      Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12

      2-wire, PROFIBUS PA/FOUNDATION Fieldbus. Ex d limiter. Usage: housing T12, Levelflex M, Micropilot M, Prosonic M.

    • Nr 35 Order code 52018949

      Terminal mod. 4-pol.,EEx ia,HART,T12,OVP

      4-pole, 2-wire. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.

    • Nr 35 Order code 52018950

      Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP

      2-pole, 2-wire. PROFIBUS PA, FOUNDATION Fieldbus. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.

  • 30
  • 40
  • 31
    • Nr 31 Order code 52024953

      HF-module FMR24x, FMR250, 26GHz

      Version uP III.3. Usage: electronics from software version 1.0, FMR250. Electronics from software version 5.0, FMR240/FMR244/FMR245, advanced dynamics.

  • 55
  • 50
  • 65
    • Nr 65 Order code 535720-9010

      Sealing kit FMR2xx

      Consists of: 2x gasket Pg13.5 FA. 2x O-ring 17.0x2.0 EPDM. 1x O-ring 49.21x3.53 EPDM. 2x O-ring 17.12x2.62 FKM. 1x O-ring 113.9x3.53 EPDM. 1x O-ring 72.0x3.0 EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250.

    • Order code 52018204

      Adaption kit housing F12, 2-wire, FHX40

      Modification to remote display. Housing F12, 2-wire electronics. Non-hazardous area only. Please order FHX40 separately. Usage: Micropilot II/M, Prosonic M, Levelflex M.

    • Order code 52016334

      Cable FHX40, 20m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 71020502

      Cable FHX40, 5m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 71020503

      Cable FHX40, 10m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 71020504

      Cable FHX40, 30m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 52013874

      Mounting bracket FHX40 1" / 2" pipe

      Usage: FHX40.

    • Order code 71133074

      Weather protection cover FMR250, FMR57

      Protection cover with lateral cable gland. Material: stainless steel. Usage: FMR250, FMR57 (200oC).

    • Order code FHX40-

      Display FHX40

      Remote display + local operation. 4-line LC-display. :: Menu driven plain text operation. :: Easy setup. :: User language selectable. :: Envelope curve display on site. Usage: FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.

    • Order code 52009925

      HF-test cable 26GHz

      Coax cable. Dummy antenna. Usage: FMR240/FMR244/FMR245/FMR250, FMR540.

    • Order code 52007646

      Tool for unplugging the antenna cable

      Usage: Micropilot M/Micropilot S.

    • Order code 71007843

      ToF Adapter FXA291

      Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.

    • Order code 71000221

      Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60

      Connection service tool RS232(52013675)/ ToF adapter FXA291 (71007843). Usage: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.

    • Order code 52007441

      Adapter cable FMR2xx/53x, FMU4x, FMP4x

      Connection > adapter. Service tool RS232 (016154-0000). To use the ToF-Tool software Micropilot M, Micropilot S, Prosonic M, Levelflex M.

    • Order code 71105889

      Horn protection, 100mm (4") horn

      Horn protection for horn antenna 100mm (4in). Consists of: PTFE disc + mounting ring. Usage: FMR51/FMR57, FMR240, FMR250.

    • Order code 71105890

      Horn protection, 80mm (3") horn

      Horn protection for horn antenna 80mm (3in). Consists of: PTFE disc + mounting ring. Usage: FMR51/FMR57, FMR240, FMR250.

    • Order code 71067434

      Modification name plate, non Ex

      Blank. To fill in the new order code when a non Ex instrument has been modified. Usage: FMB50/FMB51/FMB52, FMR230/FMR231, FMR240/FMR244/FMR245, FMR250,FMR530/FMR532,FTL50/FTL50H/FTL51/ FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/ FTL85, NMR81, PMC51, PMC71, PMP51/PMP55.

    • Order code 543199-0001

      Protective cover for housing T12/F12, SS

      Usage: Micropilot M, Micropilot S, Prosonic M, Levelflex M. Material: 316Ti.

    • Order code
  • Nástupce