Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
532 nm, 785 nm, 1000 nm
316L option
Metal: 316L stainless steel
Window: High-purity sapphire
C276 option
Metal: C276 alloy
Window: High-purity sapphire
Titanium option
Metal: Grade 2 titanium
Window: High-purity sapphire
Hybrid metal combination option
Metal: 316L stainless steel, C276 alloy
Window: High-purity sapphire
ATEX, CSA, IECEx, UKCA, JPEx
The Raman Rxn-41 probe is a rugged, process insertion probe with no sample handling system. Its single cable design streamlines installation, eliminates risk scenarios, and minimizes installation cost for long fiber runs in the process environment. The Rxn-41 probe is ideally suited for use in chemical plants and refineries to measure batch or continuous flow production. For direct measurements in cryogenic fluids, an optimized cryogenic version of the Raman Rxn-41 probe is available.
Chemical: reaction monitoring, blending, feed and final product monitoring
Polymer: polymerization reaction monitoring, polymer blending
Pharmaceutical: API reaction monitoring, crystallization, polymorph, drug substance production unit operation
Oil & Gas: fuel blending, fuel characterization
Constructed to individual site requirements
Sealed probe design
Integrated “laser on” indicator
One in/one out fiber optics
Direct insertion compatibility
Meets Category 1 pressure equipment safety standards
Suitable for hazardous area/classified environments
Jednoduché produkty
Technická výkonnost
Jednoduchost
Standardní produkty
Technická výkonnost
Jednoduchost
Špičkové produkty
Technická výkonnost
Jednoduchost
Specializované produkty
Technická výkonnost
Jednoduchost
Dle konkrétního produktu
| Výběr produktů FLEX | Technická výkonnost | Jednoduchost |
|---|---|---|
Výběr produktů z řady Fundamental Pro jednoduché aplikace |
Technická výkonnost
|
Jednoduchost
|
Výběr produktů z řady Lean Efektivně pokrývejte běžné procesní požadavky |
Technická výkonnost
|
Jednoduchost
|
Výběr produktů z řady Extended Optimalizujte své procesy inovativními technologiemi |
Technická výkonnost
|
Jednoduchost
|
Výběr produktů z řady Xpert Zvládněte i ty nejtěžší aplikace |
Technická výkonnost
|
Jednoduchost
Dle konkrétního produktu |
System design and specifications for the Raman Rxn-41 probe
| EN | CS | ||
|
08/04/2026
|
|
|
|
|
29/10/2025
|
|
|
|
|
13/12/2024
|
|
|
|
|
08/12/2023
|
|
|
|
|
10/08/2023
|
|
|
|
Jazyk: |
English |
|
Verze: |
08/04/2026 |
|
Velikost souboru: |
1.6 MB |
|
Název souboru: |
TI01673CEN_0726.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-41 probe
| EN | CS | ||
|
08/04/2026
|
|
|
|
|
29/10/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
10/08/2023
|
|
|
|
|
01/07/2022
|
|
|
|
Jazyk: |
English |
|
Verze: |
08/04/2026 |
|
Velikost souboru: |
1018.3 KB |
|
Název souboru: |
BA02190CEN_0626.pdf |
Quick start guide for the Raman Rxn-41 probe
| EN | CS | ||
|
02/12/2024
|
|
|
|
|
10/08/2023
|
|
|
|
|
01/07/2022
|
|
|
|
|
23/11/2021
|
|
|
|
Jazyk: |
English |
|
Verze: |
02/12/2024 |
|
Velikost souboru: |
1.1 MB |
|
Název souboru: |
KA01560CEN_0424.pdf |
Instructions for use of the LNG analyzer performance verification kit
| EN | CS | ||
|
30/03/2023
|
|
|
|
Jazyk: |
English |
|
Verze: |
30/03/2023 |
|
Velikost souboru: |
442.7 KB |
|
Název souboru: |
EA01470CEN_0123.pdf |
Hazardous area certifications and installation instructions
for the Raman Rxn-41 probe
| EN | CS | ||
|
21/06/2024
|
|
|
|
|
08/08/2023
|
|
|
|
|
01/07/2022
|
|
|
|
|
23/11/2021
|
|
|
|
Jazyk: |
English |
|
Verze: |
21/06/2024 |
|
Velikost souboru: |
1.3 MB |
|
Název souboru: |
XA02784CEN_0424.pdf |
化学産業および石油・ガス産業におけるガスストリームおよび LNG
の組成分析用(Raman Rxn4 アナライザー、Raman Rxn5 アナライザ
ー、Raman Rxn-30 プローブ、Raman Rxn-41 プローブを含む)、
Kaiser Raman テクノロジーによるラマン分光アナライザーおよび
プローブ製品ラインアップのご案内です。
|
Jazyk: |
Japanese |
|
Verze: |
13/05/2024 |
|
Velikost souboru: |
4.2 MB |
|
Název souboru: |
PU01445CJA_0121_RamanAnalyzer_AppGuide_OilGas_ChemInd.pdf |
Découvrez comment les systèmes de spectroscopie Raman
sont installés en toute sécurité dans des zones explosibles.
Cet article explique les risques d’ignition optique,
les concepts de protection et comment ATEX, IECEx
et les normes nordaméricaines influent sur la conception
et l’installation conformes des systèmes Raman.
|
Jazyk: |
French |
|
Verze: |
19/08/2026 |
|
Velikost souboru: |
2 MB |
|
Název souboru: |
PU01633CFR_0126-HD-ecran-ppp.pdf |
Comment la spectroscopie Raman influence
les décisions essentielles tant que des options
sont encore disponibles
|
Jazyk: |
French |
|
Verze: |
19/08/2026 |
|
Velikost souboru: |
691.9 KB |
|
Název souboru: |
PU01635CFR_0126-HD-ecran-ppp.pdf |
Comment des sites industriels sont passés
du premier signal à la création de valeur opérationnelle,
sans ralentir la production
|
Jazyk: |
French |
|
Verze: |
19/08/2026 |
|
Velikost souboru: |
933.2 KB |
|
Název souboru: |
PU01636CFR_0126-HD-ecran-ppp.pdf |
This brief targets polymerization experts and explains how inline
Raman spectroscopy can detect early process deviations and product
grade shifts.
|
Jazyk: |
English |
|
Verze: |
23/04/2026 |
|
Velikost souboru: |
344.3 KB |
|
Název souboru: |
PU01635CEN_0126.pdf |